hello, can you upload an example to help me to learn this software? and could you explain the parameter clearly?Using abbreviations is not very clear. thanks for your cool work.
Dear Ms Li,
I'm having trouble running the branch SEAS_BP7_QD_A. In the calculation, the slip rate on fault keep increasing and finally become infinity. Here are some of the output in file maxvall-BP7.dat,
0.499057199999943E+00 0.1787373E+01 0.3641661E+15 0.5391787E+15
0.499088735999943E+00 0.1855251E+01 0.4060318E+15 0.6137003E+15
0.499120271999943E+00 0.1858721E+01 NaN NaN
0.499151807999943E+00 -Infinity NaN NaN
0.499183343999944E+00 -Infinity NaN NaN
The green function was calculated by the program in file TriGreen, I've checked it and should be correct. In fact, I met the same problem when running the BP5. Do you have any idea what the problem might be?