m5stickc-plus-tlite-fw's Issues

operation power consumption increases permanently after switching the network mode

Describe the bug

The following sections were translated into English using translation tools:

Switching to networked operation mode after offline mode is started and then switching to offline mode, the system operation current will increase by about 50mA@5V.

在离线模式启动后切换至联网运行模式再切换为离线模式,系统运行电流会增加大约50mA@5V。

To reproduce

  1. Enable T-Lite in offline mode.
  2. Enter the Settings menu to cyclic switch network mode back to offline mode.
  3. Observe the system operation power consumption changes.

1.在离线模式下开启T-Lite。
2.进入设置菜单循环切换网络模式回到离线模式。
3.观察系统运行功耗变化。

Expected behavior

System operating current will be increased from 82mA@5V to 135mA@5V.

系统运行电流将从82mA@5V 增加到135mA@5V。

Screenshots

VID_20240107_023802.mp4

Environment

  • OS: M$ Windows 11
  • IDE &IDE Version: PIO Core 6.1.11
  • Repository Version: 0.0.9

Additional context

No response

Issue checklist

  • I searched for previous reports in the issue tracker
  • My report contains all necessary details

Incorrect temperatures

Describe the bug

I recently updated from the original 0.0.5 firmware to the latest one on this github (0.0.9) while the improvement was great to have, I've notice the temperature reading has been really off. Around room temperature, the reading is correct. However moving to the hotter side of the scale, The scaling seems to be very off.
IE: 75c shown on a temperature gun, shows 98cc on the t-lite
35c lightbulb showing about 45c and etc

To reproduce

Measure something hot with a secondary measurement.

Expected behavior

To show the correct temperature

Screenshots

No response

Environment

Version: 0.0.9

Additional context

No response

Issue checklist

  • I searched for previous reports in the issue tracker
  • My report contains all necessary details

Cloud Confirm Code reports "Confirm Code Wrong"

Describe the bug

Either when system is already online with cloud enabled, or the code is reset and manually saved, the code does not allow for cloud viewing.

To reproduce

  1. Open the T-lite Configuration either on screen or over LAN
  2. Choose Network
  3. Choose Cloud Online QR
  4. Scan QR Code with phone and goto link
  5. Enter 4 Code shown on T-Lite Display
  6. Code returns "Confirm code wrong"

Expected behavior

When entering code, expect to be taken to Cloud Viewer for T-Lite Display

Screenshots

20230123_185706
20230123_185810
20230123_185816

Environment

  • OS: Android / MacOS / iPadOS / Windows 10
  • IDE &IDE Version: T-Lite Firmware.exe Windows 10 1.0.0.0
  • Repository Version: 1.0.0.0

Additional context

No response

Issue checklist

  • I searched for previous reports in the issue tracker
  • My report contains all necessary details

First pixels at lower temperature in some readings

Describe the bug

Approximately one reading yes and one no, the first two pixels of the first line and the first of the second are at minimum temperature. In readings where it does not happen, the reading is correct.
The result is that when the pointer is set to the minimum temperature it moves continuously from the upper left side to the point of actual lower temperature.
I haven't been able to find much information about the T-Lite online and especially on the community so I haven't been able to understand if this is a problem that only occurs on my device or if it is actually a bug (but it could be a software bug since the defect occurs intermittently and when it is not present the readings are correct)

To reproduce

Just turn on the device with this firmware (both on version 0.0.5 and 0.0.7)

Expected behavior

Correct readings at each reading

Screenshots

Tlite4
Tlite3
Tlite2
Tlite1

Tlite.mp4

Reducing the read frequency (1Hz) and using lower temp as ref.:

Registrazione.schermo.2023-03-30.alle.23.05.48.mov

Environment

  • FW version: 0.0.7

Additional context

No response

Issue checklist

  • I searched for previous reports in the issue tracker
  • My report contains all necessary details

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.