nionio6915 / euclid_probe Goto Github PK
View Code? Open in Web Editor NEWEuclid probe, a magnetically coupled Z Probe
License: Other
Euclid probe, a magnetically coupled Z Probe
License: Other
the CAD for Voron2.4OmronRotatedXRailDock.stp has just extrusion in it. Nothing else.
The Voron 2.4 mount files under /CAD/Voron are missing the actual body for the mount.
All that are in the files are the extrusions and screws.
Please re-upload the files with the mount bodies included.
In the Railcore area the .stp files for the dock are corrupt.
Error: Autodesk Translation Services failed to translate the step file, please make sure the step file isn't corrupt!
klippy (3).log
Euclid (8).zip
print_area_bed_mesh (5).zip
hello i am using euclid probe with blvcube printer 500x500 build. i am having issues with the latest euclid commands. when using print bed mesh calibrate by turge08 stuff gets weird. assert probe command for me do not work. i get error probes already triggered. When the gcode does work I can home the bed and z tilt adjust. the probe is supposed to stow but it doesnt, the probe goes to the left of the dock and swipes it off causing an error saying probe already triggered. what do i need to change in order for this macro to work?
Hi @ALL,
unfortuanly all the CAD files in the Voron Directory are not usable.
Please reupload this files.
Best regards
Markus
RRF3_Example_Auto_Deploy_Probe_Fixed_Dock.g
Line 104
G0 X150 Y150 G3000 ; move to the center of the bed
G3000 should be F3000
RRF3_Example_Auto_Retract_Probe_Fixed_Dock.g
Line 68
G0 X0 Y70 F3000 ; move to ready position
Should be updated to be
G0 X0 Y70 F3000 ; move to Dock Re-entry staging position
Hi, I have setup everything and verified it's in NC mode and checking the pin shows that it's low, but the default M401 script is telling me that the probe is already attached when it isn't.
Fortunately QGL then fails because it recognizes it isn't there.
Here's the PROBE section in Klipper:
[probe]
pin: ^EBBCan: PB5
x_offset: 5
y_offset: -20
z_offset: 5.379
speed: 5
samples: 2
samples_result: average
sample_retract_dist: 3.0
samples_tolerance: 0.050
samples_tolerance_retries: 3
lift_speed: 30
Interestingly, after the message from the 401 comes up on the console, if you click it immediately again, it's correct and goes and gets the probe.
Note this is on an EBB-36 canbus board. I can't find any documentation on how it should be configured with that board.
hello all. i have a blvcube 500x500 i have my euclid probe set up correctly. it stowes and deploys like it should except when my mesh fails before a print. the probe stays in the last position it was in, when i home the probe is still attached and collides with its dock. what do i need to do in order for my probe to remesh/ redock/ or stay connected and just rehome xyz and mesh again without having to use m401 and m402
Probe.zip
Euclid (2).zip
On the main Voron installation guide:
https://euclidprobe.github.io/02c_Voron2.html#clockwork2--stealthburner-native-mounts
it is mentioned under section "Clockwork2 & Stealthburner Native Mounts" that
The left and right halves of the native carriage shells for Voron Stealthburner / CW2 / Clockwork 2 have been modified to accept the probe with M2.5 self tapping screws from underneath.
Though the provided screws in the kit are to long to fit and will split the printed part "Clockwork2_Euclid_MGN12X_RIGHT_Carriage_Ver2.stl" (Link) open rendering it unusable.
I would strongly suggest to implement the mounting holes either deeper or as full thru-holes instead of pocket holes. As an alternative, heatset inserts may be a more viable solution, too, certainly preventing splitting the printed part in that kind of delicate area.
I noticed that schematic / gerber files are not included into github repository. Is there a reason for that?
Hey mind sharing your homexy too?
I'm trying to customize mounting, but your STLs won't convert to solid well. Would it be possible to supply STEP files as well? I'd be happy to share my results with you.
Klipper version: v0.10.0-387
Error:
Error loading template 'gcode_macro DEPLOY_PROBE:gcode': TemplateSyntaxError: expected token 'end of print statement', got 'DOCK'
Happens without any modification to original file
When using the Euclide probe on a V-Core 3 - 400 Machine while running RatOS and having a Z-Offset >=+5mm the Code in the line 136 of "00-euclid_exampleV5.cfg", G0 Z5, will make the Bed move in the wron direction after homing Z. If the Z-Offset is <5mm this wont happen and the bed will move as expected after homing.
FIX: Change the value for Z in the line 136 so that is is always strictly larger than your Z-Offset
A declarative, efficient, and flexible JavaScript library for building user interfaces.
๐ Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.
TypeScript is a superset of JavaScript that compiles to clean JavaScript output.
An Open Source Machine Learning Framework for Everyone
The Web framework for perfectionists with deadlines.
A PHP framework for web artisans
Bring data to life with SVG, Canvas and HTML. ๐๐๐
JavaScript (JS) is a lightweight interpreted programming language with first-class functions.
Some thing interesting about web. New door for the world.
A server is a program made to process requests and deliver data to clients.
Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.
Some thing interesting about visualization, use data art
Some thing interesting about game, make everyone happy.
We are working to build community through open source technology. NB: members must have two-factor auth.
Open source projects and samples from Microsoft.
Google โค๏ธ Open Source for everyone.
Alibaba Open Source for everyone
Data-Driven Documents codes.
China tencent open source team.