Hello,
I'm using SMAspot 2.4.1 on a raspberry pi.
I have a STP 12000TL-10 inverter, a SMA homemanager and three SMA bluetooth plug-in receiver (Funksteckdose)
If the homemanager is connected to the inverter via bt i can only use installer mode do connect. Then I get data from all three plugins, but the first one has strange values. The second and third one has always 0.0 values. It looks like, as if the plug-ins are treated as an inverter.
From the inverter i somtimes get data and somtimes not.
How can i remove the bluetooth plug-in from the list and get only data from the inverter? Do you have an idea? And how can i use the normal login instead of the installer login during a connection to the homemanager is active? If i should deliver more data dont hesitate to ask. ;-)
Here is the Output from SMAspot from tonight.
SMAspot V2.4.1
Yet another tool to read power production of SMA solar inverters
(c) 2012-2014, SBF (https://smaspot.codeplex.com)
Compiled for Linux 32 bit
Commandline Args: -v -finq -installer -password:Xxxxx
Reading config './SMAspot.cfg'
Wed Feb 19 21:43:44 2014: INFO: Starting...
sunrise: 07:20
sunset : 17:40
Connecting to 00:80:25:xx:xx:Xx (1/10)
Initializing...
SUSyID: 125 - SN: 886832786 (0x34DBFE92)
SMA netID=02
SUSyID: 128 - SN: xxxxxxxxxx
SUSyID: 191 - SN: xxxxxxxxxx
SUSyID: 191 - SN: xxxxxxxxxx
SUSyID: 191 - SN: xxxxxxxxxx
BT Signal=75%
Logon OK
Local Time: 19/02/2014 21:43:46
TZ offset (s): 3600 - DST: Off
SUSyID: 191 - SN: xxxxxxxxxx
Device Name: Computerschrank 463
Device Class: Verbraucher
Device Type: SMA Funksteckdose
Software Version: 12.12.108.R
Serial number: xxxxxxxxxx
SUSyID: 191 - SN: xxxxxxxxxx
Device Name: Büro 566
Device Class: Verbraucher
Device Type: SMA Funksteckdose
Software Version: 12.12.108.R
Serial number: xxxxxxxxxx
SUSyID: 191 - SN: xxxxxxxxxx
Device Name: Waschmaschine 890
Device Class: Verbraucher
Device Type: SMA Funksteckdose
Software Version: 12.12.108.R
Serial number: xxxxxxxxxx
SUSyID: 128 - SN: xxxxxxxxxx
Device Name: SN: xxxxxxxxxx
Device Class: Solar-Wechselrichter
Device Type: STP 12000TL-10
Software Version: 02.55.13.R
Serial number: xxxxxxxxxx
SUSyID: 191 - SN: xxxxxxxxxx
Device Status: Ok
SUSyID: 191 - SN: xxxxxxxxxx
Device Status: Ok
SUSyID: 191 - SN: xxxxxxxxxx
Device Status: Ok
SUSyID: 128 - SN: xxxxxxxxxx
Device Status: Ok
SUSyID: 191 - SN: xxxxxxxxxx
Device Temperature: 8423488.0°C
SUSyID: 191 - SN: xxxxxxxxxx
Device Temperature: 0.0°C
SUSyID: 191 - SN: xxxxxxxxxx
Device Temperature: 0.0°C
SUSyID: 128 - SN: xxxxxxxxxx
Device Temperature: 0.0°C
SUSyID: 191 - SN: xxxxxxxxxx
Pac max phase 1: 1299333462W
Pac max phase 2: 1715692655W
Pac max phase 3: 1096167015W
SUSyID: 191 - SN: xxxxxxxxxx
Pac max phase 1: 0W
Pac max phase 2: 0W
Pac max phase 3: 0W
SUSyID: 191 - SN: xxxxxxxxxx
Pac max phase 1: 0W
Pac max phase 2: 0W
Pac max phase 3: 0W
SUSyID: 128 - SN: xxxxxxxxxx
Pac max phase 1: 12000W
Pac max phase 2: 12000W
Pac max phase 3: 12000W
SUSyID: 191 - SN: xxxxxxxxxx
Energy Production:
EToday: 7020378737416761.000kWh
ETotal: 3760841250522883.000kWh
Operation Time: 12800.92h
Feed-In Time : 1623830055690497.50h
SUSyID: 191 - SN: xxxxxxxxxx
Energy Production:
EToday: 0.000kWh
ETotal: 0.000kWh
Operation Time: 12801.27h
Feed-In Time : 0.00h
SUSyID: 191 - SN: xxxxxxxxxx
Energy Production:
EToday: 0.000kWh
ETotal: 0.000kWh
Operation Time: 12794.29h
Feed-In Time : 0.00h
SUSyID: 128 - SN: xxxxxxxxxx
Energy Production:
EToday: 11.542kWh
ETotal: 21033.739kWh
Operation Time: 7448.15h
Feed-In Time : 7247.82h
SUSyID: 191 - SN: xxxxxxxxxx
DC Spot Data:
String 1 Pdc: 1835353.125kW - Udc: 8253074.00V - Idc: 1919252.125A
String 2 Pdc: 224685.656kW - Udc: 12287478.00V - Idc: 779249.000A
SUSyID: 191 - SN: xxxxxxxxxx
DC Spot Data:
String 1 Pdc: 0.000kW - Udc: 0.00V - Idc: 0.000A
String 2 Pdc: 0.000kW - Udc: 0.00V - Idc: 0.000A
SUSyID: 191 - SN: xxxxxxxxxx
DC Spot Data:
String 1 Pdc: 0.000kW - Udc: 0.00V - Idc: 0.000A
String 2 Pdc: 0.000kW - Udc: 0.00V - Idc: 0.000A
SUSyID: 128 - SN: xxxxxxxxxx
DC Spot Data:
String 1 Pdc: 0.000kW - Udc: 0.00V - Idc: 0.000A
String 2 Pdc: 0.000kW - Udc: 0.00V - Idc: 0.000A
SUSyID: 191 - SN: xxxxxxxxxx
AC Spot Data:
Phase 1 Pac : 1734755.250kW - Uac: 9623587.00V - Iac: 1684957.625A
Phase 2 Pac : 778333.500kW - Uac: 8084665.00V - Iac: 1936287.125A
Phase 3 Pac : 1316110.750kW - Uac: 11133384.00V - Iac: 1735292.250A
Total Pac : 1936606.125kW
SUSyID: 191 - SN: xxxxxxxxxx
AC Spot Data:
Phase 1 Pac : 0.000kW - Uac: 0.00V - Iac: 0.000A
Phase 2 Pac : 0.000kW - Uac: 0.00V - Iac: 0.000A
Phase 3 Pac : 0.000kW - Uac: 0.00V - Iac: 0.000A
Total Pac : 0.000kW
SUSyID: 191 - SN: xxxxxxxxxx
AC Spot Data:
Phase 1 Pac : 0.000kW - Uac: 0.00V - Iac: 0.000A
Phase 2 Pac : 0.000kW - Uac: 0.00V - Iac: 0.000A
Phase 3 Pac : 0.000kW - Uac: 0.00V - Iac: 0.000A
Total Pac : 0.000kW
SUSyID: 128 - SN: xxxxxxxxxx
AC Spot Data:
Phase 1 Pac : 0.000kW - Uac: 0.00V - Iac: 0.000A
Phase 2 Pac : 0.000kW - Uac: 0.00V - Iac: 0.000A
Phase 3 Pac : 0.000kW - Uac: 0.00V - Iac: 0.000A
Total Pac : 0.000kW
SUSyID: 191 - SN: xxxxxxxxxx
Grid Freq. : 18192434.00Hz
SUSyID: 191 - SN: xxxxxxxxxx
Grid Freq. : 0.00Hz
SUSyID: 191 - SN: xxxxxxxxxx
Grid Freq. : 0.00Hz
SUSyID: 128 - SN: xxxxxxxxxx
Grid Freq. : 0.00Hz
ArchiveDayData() *
startTime = 5303E5F0 -> 19/02/2014 00:00:00
ExportDayDataToCSV()
ArchiveMonthData() *
startTime = 52ECD3B0 -> 01/02/2014 12:00:00
ExportMonthDataToCSV()
There is no data to export!
Reading events: 2014-Feb-01
ExportEventsToCSV()
Wed Feb 19 21:43:54 2014: INFO: Done.
pi@piusb ~/fhem/sma241/bin/Release
Attachments
Archiv.zip
Archiv.zip
This work item was migrated from CodePlex
CodePlex work item ID: '16'
Vote count: '1'