Giter Site home page Giter Site logo

u9n / hanporten Goto Github PK

View Code? Open in Web Editor NEW
33.0 33.0 12.0 3.06 MB

An information page about the local customer interface in Swedish electricity meters. Also called the HAN port or P1 port

License: Creative Commons Attribution Share Alike 4.0 International

HTML 100.00%
h1 han-port p1 smart-home smart-meter smarthome

hanporten's People

Contributors

albatorsk avatar apayerl avatar henriksolver avatar krolken avatar michaelsjogren avatar simontegelid avatar

Stargazers

 avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar

Watchers

 avatar  avatar  avatar

hanporten's Issues

Document Tekniska verken RJ12

Tekniska Verken uses an Aidon meter that has an RJ12 connector but pushes a HDLC frame containing a DataNotification APDU.

Document the deviance from standard and add code example to parse the data.

Certificate error https

Seems to be trouble with the https certificate. Says on iOS safari issued by GitHub. Try toggling https to make it reissue a new cert from let's encrypt.

Data to be used when calculating CRC

Hi,

I have the swedish net owner Ellevio, and a Segemcom S211 meter.
When calculating the message checksum, the characters '/' and '!' needs to be added in the calculation.

Under "Svenska porten (RJ12)" -> Protokollet, paragraph "Meddelandestruktur" it says:

"Datan som skall användas i beräkningen är de byte som är mellan / och !."

This is wrong. '/' and '!' must be added in the CRC calculation.

Best regards /M

Anslutning till hanport via com-port hw-schema

Han-comport
hanporten.se är utmärkt för att samla uppgifter kring de nya elmätarna och dess RJ12-anslutning.
tänkte bidraga med lite hw-schema för koppling till en vanlig DB-9-kontakt.
Varför sidans inverterade signal finns med förstår jag ej. Dessutom är det schemat inte att rekommendera. Om någon vill ha eller behöver inverterade signaler har jag ett bättre förslag.
Synpunkter på detta mottages.
/Henrik Bergman

Rj45 vs Rj11/12

På marknaden verkar just nu de flesta tillverkare av smart hemutrustning använda rj45 för att ansluta till elmätaren. Men samtidigt har många mätare rj11 eller rj12. Skulle ni säga att det är möjligt att göra en adapter mellan dessa två fysiska gränssnitt?

Add information about standard IEC62056-21

It seems like it might be optional to either use the P1 Companion standard or standard IEC62056-21 on the protocol

So either

115200 baud, 8N1 + 2 byte CRC

or

9600 baud, 7E1, 1 byte BCC

I am in contact with the writers of the recomendation on which was intended but I have seen meters with the standard IEC62056-21

Sluta kalla P1 för HAN !

Antingen är det P1 eller HAN, men i Sverige är det P1 som gäller och inte norska HAN med Mbus.

DIY för Landys and Gyr E360

Hej, det finns ett par github repos som har relativt enkla och billiga lösningar beroende på vad man är ute efter.
Dels https://github.com/udok/esp8266_p1meter_sv som jag själv använder för att få in data till HomeAssistant men även https://github.com/psvanstrom/esphome-p1reader.

Båda utgår från programmerbara microprocessorer (nodemcu, d1 mini) som kostar mellan 50-150 sek och utöver det behöver man ett 10 ohms motstånd och en RJ12 sladd.

Är det något som kan va intressant att lägga in under lösningar?

Activation of HAN on EON

Hi!

There is an update (so, now a fact error) for EON. Under "Mina avtal" it is now possible to (de)activate the HAN port.

image

Clicking it will toggle it to:

image

Swedish E.on E360 F3_100 integration with Smartthings

Saw you website and got here, of course with a star vote!

Now, I'm trying to get some real time data to smartthings. I want to for example only allow some appliances to start if PV power is over a certain limit etc...

Which HAN device would be suitable for that and could we help making a device handler? I would imagine in Sweden loads of people got e.on meters and smartthings...

Some are written about the Norwegian HAN here, I don't know if it is of any use as I don't know if the same company has a RJ12 compatible device for me in Sweden.
https://community.smartthings.com/t/new-zigbee-device-handler-for-emi-han-meter/176661

Thanks for any help!

EEM Elnät och SEVAB Nät HAN-port

Hej! Vi tycker att HAN-porten är bra utveckling för elmätarna och er webbsida hanporten.se sprider fakta om olika typer av HAN-portar på ett mycket bra sätt. Vi skulle gärna se att ni inkluderar info om HAN-porten från de nätföretag vi representerar, Eskilstuna Energi och Miljö Elnät och SEVAB Nät. Informationsspridning är viktig då vi inser att vi får en del kundfrågor som skulle kunna avvärjas med större informationsspridning. Våra elmätare från Aidon följer den svenska branschrekommendationen (RJ12) och vi har också författat särskilda allmänna villkor för de kunder som väljer att aktivera HAN-porten. Begäran om aktivering och inaktivering gör man i första hand via webbformulär på våra sidor. I skrivande stund så har SEVAB bytt ut de allra flesta av sina elmätare till nya med HAN-port medan EEM ska påbörja stora utrullningen av nya elmätare under 2022. Här har vi samlat info på våra webbsidor (sidorna är författade lika hos de olika bolagen):
http://www.eem.se/privat/elnat/elmatare/han-porten/
http://www.sevab.com/privat/elnat/elmatare/han-porten/

Med förhoppning om stor framtida nytta av HAN-portar!

mvh Dan Jisei
Eskilstuna Strängnäs Energi och Miljö

Legacy AM550 for E.ON will not enable HAN.

E.ON has a legacy meter (Iskra AM550) with an RJ12 HAN-port. But since E.ON plans to exchange them for newer there is no internal process to activate the port.

Add on page about E.ON to make it a bit clearer that it will not work.

Nacka Energi och Kaifa CL 109

Nacka Energi installerar just nu en Kaifa CL 109 (MA304H4E) i hela kommunen. Den har en RJ12 HAN-port och ser ut som enligt bild:
2021-09-22 23 58 39

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.