* SMMON [DSQDC] - DECSYSTEM 2020 DIAGNOSTIC MONITOR - VER 0.3 *
SMMON CMD - DSRPA
DECSYSTEM 2020 RP06-RH11 BASIC DRIVE DIAGNOSTIC [DSRPA]
VERSION 0.3, SV=0.3, CPU#=4097, MCV=130, MCO=470, HO=0, KASW=003740 000000
TTY SWITCH CONTROL ? - 0,S OR Y <CR> - Y
LH SWITCHES <# OR ?> - 400000
RH SWITCHES <# OR ?> - 400000
SWITCHES = 400000 400000
MEMORY MAP =
FROM TO SIZE/K
00000000 03777777 1024
**********
CAUTION - - MOUNT SCRATCH PACK(S) BEFORE RUNNING.
THIS DIAG. WRITES THE PACK. IF AN 11-FMT SCRATCH PACK IS USED,
IT WILL HAVE TO BE REFORMATED AFTER RUNNING THIS DIAG.
**********
HEAD ALIGNMENT AND DUAL PORT TESTS DO NOT WRITE THE PACK
LIST PGM SWITCH OPTIONS ? Y OR N <CR> - N
ALL DRIVES BEING TESTED SHOULD BE LOCKED ON PROPER PORT
WITH DEVICE SELECT PLUG INSTALLED
UNLESS INSTRUCTED OTHERWISE ...
THE FOLLOWING RP06'S ARE DETECTED
0, 1, 2
SELECT DRIVES (0-7 OR "A") - 0
*PGM TRACE* TEST-001 PC-030711 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-002 PC-030764
*PGM TRACE* TEST-003 PC-031012
*PGM TRACE* TEST-004 PC-031015
*PGM TRACE* TEST-005 PC-031052
*PGM TRACE* TEST-006 PC-031105
*PGM TRACE* TEST-007 PC-031145
*PGM TRACE* TEST-010 PC-031203
*PGM TRACE* TEST-011 PC-031240
*PGM TRACE* TEST-012 PC-031271
*PGM TRACE* TEST-013 PC-031325
*PGM TRACE* TEST-014 PC-031365
*PGM TRACE* TEST-015 PC-031424
*PGM TRACE* TEST-016 PC-031462
*PGM TRACE* TEST-017 PC-031512
*PGM TRACE* TEST-020 PC-031544
*PGM TRACE* TEST-021 PC-031604
*PGM TRACE* TEST-022 PC-031641
*PGM TRACE* TEST-023 PC-031675
*PGM TRACE* TEST-024 PC-031724
*PGM TRACE* TEST-025 PC-031752
*PGM TRACE* TEST-026 PC-032002
*PGM TRACE* TEST-027 PC-032026
*PGM TRACE* TEST-030 PC-032052
*PGM TRACE* TEST-031 PC-032101
*PGM TRACE* TEST-032 PC-032127
*PGM TRACE* TEST-033 PC-032156
*PGM TRACE* TEST-034 PC-032202
*PGM TRACE* TEST-035 PC-032231
*PGM TRACE* TEST-036 PC-032264
*PGM TRACE* TEST-037 PC-032341
*PGM TRACE* TEST-040 PC-032405
*PGM TRACE* TEST-041 PC-032434
*PGM TRACE* TEST-042 PC-032461
*PGM TRACE* TEST-043 PC-032511
*PGM TRACE* TEST-045 PC-032556
*PGM TRACE* TEST-046 PC-032611
*PGM TRACE* TEST-047 PC-032642
*PGM TRACE* TEST-050 PC-032671
*PGM TRACE* TEST-051 PC-032722
*PGM TRACE* TEST-052 PC-032725
*PGM TRACE* TEST-053 PC-032773
*PGM TRACE* TEST-054 PC-033115
*PGM TRACE* TEST-055 PC-033145
*PGM TRACE* TEST-056 PC-033175
*PGM TRACE* TEST-057 PC-033225
*PGM TRACE* TEST-060 PC-033253
*PGM TRACE* TEST-061 PC-033304
*PGM TRACE* TEST-062 PC-033333
*PGM TRACE* TEST-063 PC-033363
*PGM TRACE* TEST-064 PC-033411
*PGM TRACE* TEST-065 PC-033531
*PGM TRACE* TEST-066 PC-033563
*PGM TRACE* TEST-067 PC-033712
*PGM TRACE* TEST-070 PC-034011
*PGM TRACE* TEST-071 PC-034110
*PGM TRACE* TEST-072 PC-034140
*PGM TRACE* TEST-073 PC-034255
*PGM TRACE* TEST-074 PC-034350
*PGM TRACE* TEST-075 PC-034401
*PGM TRACE* TEST-076 PC-034431
*PGM TRACE* TEST-077 PC-034462
*PGM TRACE* TEST-100 PC-034536
*PGM TRACE* TEST-101 PC-034567
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST1 PC-054323
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST2 PC-054356
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST3 PC-054413
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST4 PC-054446
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST5 PC-054567
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST6 PC-054676
TST-101 SUBTEST: *PGM TRACE* TEST-RHTST7 PC-054755
TST-101 SUBTEST: *PGM TRACE* TEST-RHTS10 PC-055023
*PGM TRACE* TEST-102 PC-034612
*PGM TRACE* TEST-103 PC-034645
*PGM TRACE* TEST-104 PC-034701
*PGM TRACE* TEST-105 PC-034733
*PGM TRACE* TEST-106 PC-034767
*PGM TRACE* TEST-107 PC-035020
*PGM TRACE* TEST-110 PC-035051
*PGM TRACE* TEST-111 PC-035102
*PGM TRACE* TEST-112 PC-035135
*PGM TRACE* TEST-113 PC-035167
*PGM TRACE* TEST-114 PC-035221
*PGM TRACE* TEST-115 PC-035252
*PGM TRACE* TEST-116 PC-035372
*PGM TRACE* TEST-117 PC-035431
*PGM TRACE* TEST-120 PC-035474
*PGM TRACE* TEST-121 PC-035477
*PGM TRACE* TEST-122 PC-035625
*PGM TRACE* TEST-123 PC-035667
*PGM TRACE* TEST-124 PC-035732
*PGM TRACE* TEST-125 PC-035735
*PGM TRACE* TEST-126 PC-036032
*PGM TRACE* TEST-127 PC-036074
*PGM TRACE* TEST-130 PC-036137
*PGM TRACE* TEST-131 PC-036142
*PGM TRACE* TEST-132 PC-036243
*PGM TRACE* TEST-133 PC-036310
*PGM TRACE* TEST-134 PC-036353
*PGM TRACE* TEST-135 PC-036356
*PGM TRACE* TEST-136 PC-036405
*PGM TRACE* TEST-137 PC-036436
*PGM TRACE* TEST-140 PC-036465
*PGM TRACE* TEST-141 PC-036514
*PGM TRACE* TEST-142 PC-036537
*PGM TRACE* TEST-143 PC-036566
*PGM TRACE* TEST-144 PC-036623
*PGM TRACE* TEST-145 PC-036652
*PGM TRACE* TEST-146 PC-036701
*PGM TRACE* TEST-147 PC-036730
*PGM TRACE* TEST-150 PC-036757
*PGM TRACE* TEST-151 PC-037006
*PGM TRACE* TEST-152 PC-037034
*PGM TRACE* TEST-153 PC-037065
*PGM TRACE* TEST-154 PC-037204
*PGM TRACE* TEST-155 PC-037243
*PGM TRACE* TEST-156 PC-037306
*PGM TRACE* TEST-157 PC-037311
*PGM TRACE* TEST-160 PC-037374
*PGM TRACE* TEST-161 PC-037431
*PGM TRACE* TEST-162 PC-037503
*PGM TRACE* TEST-163 PC-037550
*PGM TRACE* TEST-164 PC-037614
*PGM TRACE* TEST-165 PC-037653
*PGM TRACE* TEST-166 PC-040006
*PGM TRACE* TEST-167 PC-040135 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-170 PC-040273 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-171 PC-040351 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-172 PC-040413
*PGM TRACE* TEST-173 PC-040446
*PGM TRACE* TEST-174 PC-040504
*PGM TRACE* TEST-175 PC-040551
*PGM TRACE* TEST-176 PC-040602
*PGM TRACE* TEST-177 PC-040650
*PGM TRACE* TEST-200 PC-040723
*PGM TRACE* TEST-201 PC-041037
*PGM TRACE* TEST-202 PC-041070
*PGM TRACE* TEST-203 PC-041121
*PGM TRACE* TEST-204 PC-041153
*PGM TRACE* TEST-205 PC-041202
*PGM TRACE* TEST-206 PC-041272
*PGM TRACE* TEST-207 PC-041316
*PGM TRACE* TEST-210 PC-041342
*PGM TRACE* TEST-211 PC-041367
*PGM TRACE* TEST-212 PC-041415
*PGM TRACE* TEST-213 PC-041444
*PGM TRACE* TEST-214 PC-041473
*PGM TRACE* TEST-215 PC-041530
*PGM TRACE* TEST-216 PC-041604
*PGM TRACE* TEST-217 PC-041635
*PGM TRACE* TEST-220 PC-041666
*PGM TRACE* TEST-221 PC-041717
*PGM TRACE* TEST-222 PC-041750
*PGM TRACE* TEST-223 PC-042001
*PGM TRACE* TEST-224 PC-042032
*PGM TRACE* TEST-225 PC-042062
*PGM TRACE* TEST-226 PC-042113
*PGM TRACE* TEST-227 PC-042144
*PGM TRACE* TEST-230 PC-042177
*PGM TRACE* TEST-231 PC-042234
*PGM TRACE* TEST-232 PC-042266
*PGM TRACE* TEST-233 PC-042317
*PGM TRACE* TEST-234 PC-042350
*PGM TRACE* TEST-235 PC-042402
*PGM TRACE* TEST-236 PC-042433
*PGM TRACE* TEST-237 PC-042464
*PGM TRACE* TEST-240 PC-042516
*PGM TRACE* TEST-241 PC-042547
*PGM TRACE* TEST-242 PC-042600
*PGM TRACE* TEST-243 PC-042631
*PGM TRACE* TEST-244 PC-042657
*PGM TRACE* TEST-245 PC-042662
*PGM TRACE* TEST-246 PC-042724
*PGM TRACE* TEST-247 PC-042762
*PGM TRACE* TEST-250 PC-043103
*PGM TRACE* TEST-251 PC-043145
*PGM TRACE* TEST-252 PC-043205
*PGM TRACE* TEST-253 PC-043247
*PGM TRACE* TEST-254 PC-043307
*PGM TRACE* TEST-255 PC-043352
*PGM TRACE* TEST-256 PC-043412
*PGM TRACE* TEST-257 PC-043455
*PGM TRACE* TEST-260 PC-043516
*PGM TRACE* TEST-261 PC-043603
*PGM TRACE* TEST-262 PC-043710
*PGM TRACE* TEST-264 PC-043756
*PGM TRACE* TEST-265 PC-044010
*PGM TRACE* TEST-266 PC-044054
*PGM TRACE* TEST-267 PC-044153
*PGM TRACE* TEST-270 PC-044213
*PGM TRACE* TEST-271 PC-044335
*PGM TRACE* TEST-272 PC-044500
*PGM TRACE* TEST-273 PC-044537
*PGM TRACE* TEST-274 PC-044613
*PGM TRACE* TEST-275 PC-044664
*PGM TRACE* TEST-276 PC-044723
*PGM TRACE* TEST-277 PC-045001
*PGM TRACE* TEST-300 PC-045044
*PGM TRACE* TEST-301 PC-045100
*PGM TRACE* TEST-302 PC-045144
*PGM TRACE* TEST-303 PC-045307 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-304 PC-045402 *TEST OMITTED. NO "OPRSEL"*
*PGM TRACE* TEST-305 PC-045540
*PGM TRACE* TEST-306 PC-045601
*PGM TRACE* TEST-307 PC-045637
*PGM TRACE* TEST-310 PC-045721
*PGM TRACE* TEST-311 PC-045765
*PGM TRACE* TEST-312 PC-046014
*PGM TRACE* TEST-313 PC-046043
*PGM TRACE* TEST-314 PC-046075
*PGM TRACE* TEST-315 PC-046123
*PGM TRACE* TEST-316 PC-046167
*PGM TRACE* TEST-317 PC-046256
*PGM TRACE* TEST-320 PC-046313
*PGM TRACE* TEST-321 PC-046343
*PGM TRACE* TEST-322 PC-046374
*PGM TRACE* TEST-323 PC-046431
*PGM TRACE* TEST-325 PC-046463
*PGM TRACE* TEST-326 PC-046555
*PGM TRACE* TEST-327 PC-046732
*PGM TRACE* TEST-330 PC-047222
*PGM TRACE* TEST-331 PC-047322
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 7.
DATA ACROSS THE MASS BUS = 000001
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 8.
DATA ACROSS THE MASS BUS = 000002
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 9.
DATA ACROSS THE MASS BUS = 000004
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 10.
DATA ACROSS THE MASS BUS = 000010
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 11.
DATA ACROSS THE MASS BUS = 000020
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 12.
DATA ACROSS THE MASS BUS = 000040
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 13.
DATA ACROSS THE MASS BUS = 000100
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 14.
DATA ACROSS THE MASS BUS = 000200
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 15.
DATA ACROSS THE MASS BUS = 000400
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 16.
DATA ACROSS THE MASS BUS = 001000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 17.
DATA ACROSS THE MASS BUS = 002000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 18.
DATA ACROSS THE MASS BUS = 004000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 19.
DATA ACROSS THE MASS BUS = 010000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 20.
DATA ACROSS THE MASS BUS = 020000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 21.
DATA ACROSS THE MASS BUS = 040000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 22.
DATA ACROSS THE MASS BUS = 100000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 23.
DATA ACROSS THE MASS BUS = 200000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 24.
DATA ACROSS THE MASS BUS = 400000
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 25.
DATA ACROSS THE MASS BUS = 777776
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 26.
DATA ACROSS THE MASS BUS = 777775
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 27.
DATA ACROSS THE MASS BUS = 777773
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 28.
DATA ACROSS THE MASS BUS = 777767
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 29.
DATA ACROSS THE MASS BUS = 777757
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 30.
DATA ACROSS THE MASS BUS = 777737
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 31.
DATA ACROSS THE MASS BUS = 777677
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 32.
DATA ACROSS THE MASS BUS = 777577
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 33.
DATA ACROSS THE MASS BUS = 777377
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 34.
DATA ACROSS THE MASS BUS = 776777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 35.
DATA ACROSS THE MASS BUS = 775777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 36.
DATA ACROSS THE MASS BUS = 773777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 37.
DATA ACROSS THE MASS BUS = 767777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 38.
DATA ACROSS THE MASS BUS = 757777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 39.
DATA ACROSS THE MASS BUS = 577777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
ERROR: TEST-331 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 047364 START ADR OF TEST = 047322
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177400 WORD CNT = 177400
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000201 DA-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T FLOAT PATTERNS OVER WRITE DATA PATH CORRECTLY
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 40.
DATA ACROSS THE MASS BUS = 377777
DATA AT DRIVES MAINT REG = 000000
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M7776 - EC ROW-5
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
M7773 - SN ROW-6
----------------------------------------
*PGM TRACE* TEST-332 PC-047424
*PGM TRACE* TEST-333 PC-047512
*PGM TRACE* TEST-334 PC-047515
*PGM TRACE* TEST-335 PC-047776
*PGM TRACE* TEST-336 PC-050042
ERROR: TEST-336 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050106 START ADR OF TEST = 050042
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 001001 SYNBIT M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
FAULTY STATUS DOING M-MODE READ HEADER + DATA
SHOULD HAVE: DATA ENV=1 FER=0 HCRC=0 HCE=0
M7773 - SN ROW-6
M7786 - SS ROW-7
----------------------------------------
*PGM TRACE* TEST-337 PC-050117
*PGM TRACE* TEST-340 PC-050177
ERROR: TEST-340 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050247 START ADR OF TEST = 050177
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 004000 HIREQ HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 144272 SC TRE DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 050700 ERR MOL DPR DRY VV
DRER1 1776714-0: 000400 HCRC
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000001 SURFACE=0, SECTOR=1
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
DRIVE FAILED TO DETECT "HCE" WHEN WRONG CYCLINDER
DATA WAS SENT BY DIAGNOSTIC
M7786 - SS ROW-7
M7773 - SN ROW-6
----------------------------------------
*PGM TRACE* TEST-341 PC-050257
ERROR: TEST-341 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050324 START ADR OF TEST = 050257
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 004000 HIREQ HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 144272 SC TRE DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 050700 ERR MOL DPR DRY VV
DRER1 1776714-0: 000400 HCRC
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000001 SURFACE=0, SECTOR=1
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
DRIVE FAILED TO DETECT FORMAT ERROR
DRIVE IN 18 BIT MODE. DIAGNOSTIC FURNISHED
HEADER DATA FOR 16 BIT MODE
M7786 - SS ROW-7
M7773 - SN ROW-6
----------------------------------------
*PGM TRACE* TEST-342 PC-050335
*PGM TRACE* TEST-343 PC-050411
*PGM TRACE* TEST-344 PC-050452
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050560 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T SEND CONSTANT DATA THROUGH DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 2.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 3.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000001
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 4.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000002
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 5.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000004
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 6.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000010
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 7.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000020
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 8.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000040
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 9.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000100
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 10.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000200
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 11.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 000400
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 12.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 001000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 13.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 002000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 14.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 004000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 15.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 010000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 16.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 020000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 17.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 040000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 18.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 100000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 19.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 200000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 20.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 400000
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 21.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777776
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 22.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777775
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 23.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777773
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 24.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777767
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 25.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777757
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 26.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777737
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 27.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777677
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 28.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777577
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 29.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 777377
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 30.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 776777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 31.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 775777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 32.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 773777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 33.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 767777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 34.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 757777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 35.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 577777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050600 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER FLOATING PATTERNS OVER DATA PATH
ERROR ON AN 18. BIT XFER OVER DATA BUSS. ERROR WAS ON TRANSFER # 36.
DATA ACROSS THE MASS BUS = 000000
DATA AT DRIVES MAINT REG = 377777
M7773 - SN ROW-6
M7776 - EC ROW-5
REPLACE TRANSCEIVERS CARRYING FAILING BITS ONLY
(CHECK FOR CABLE OR TERMINATOR PROBLEMS)
M5903 - XCVR ROW-1 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-1 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-2 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-2 SLOTS A&B (PORT-B)
M5903 - XCVR ROW-3 SLOTS E&F (PORT-A)
M5903 - XCVR ROW-3 SLOTS A&B (PORT-B)
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
ERROR: TEST-344 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 050624 START ADR OF TEST = 050452
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004272 DVA RDY FNCTN(30-34)=RDH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000001 M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
CAN'T XFER MISC. DATA PATTERNS OVER DATA PATH
DIFFICULT FAULT. CONSTANT AND FLOATING PATTERNS
HAVE ALREADY WORKED
MODULE CALLOUT WOULD BE IMPOSSIBLE
----------------------------------------
*PGM TRACE* TEST-345 PC-050656
*PGM TRACE* TEST-346 PC-051017
*PGM TRACE* TEST-347 PC-051043
*PGM TRACE* TEST-350 PC-051073
ERROR: TEST-350 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 051130 START ADR OF TEST = 051073
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 177374 WORD CNT = 177374
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004063 DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
DRSR 1776712-0: 010500 MOL DPR VV
DRER1 1776714-0: 000000
DRMR 1776724-0: 000101 EC-ENV M-MODE
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DRLA 1776720-0: 000000 SECTOR=0 EXTENSION=0
DROF 1776732-0: 002000 HC-INH OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
ECC GENERATOR HAS PUT OUT INCORRECT DATA
ECC FIELD CORRECT= 024413 142000
ECC FIELD ACTUAL = 000000 000000
M7776 - EC ROW-5
----------------------------------------
*PGM TRACE* TEST-351 PC-051154
DEVICE TIMEOUT (HUNG) DRIVE-0
RHCS1 1776700-0: 144063 SC TRE DVA FNCTN(30-34)=WRTH+D, GO-BIT=1
PGM WAS WAITING AT PC - 056147
ERROR: TEST-351 RH BASE ADR-1776700 DRIVE-0
SCOPE PC = 051212 START ADR OF TEST = 051154
DATA SWITCHES = 400000 400000
UBAS 1763100: 000000 000000 HI PIA=0, LO PIA=0
RHCS2 1776710: 000100 IR DRIVE=0
RHWC 1776702: 000000 WORD CNT = 000000
RHBA 1776704: 000000 BUS ADDR = 000000
RHCS1 1776700-0: 004262 DVA RDY FNCTN(30-34)=WRTH+D, GO-BIT=0
DRSR 1776712-0: 010700 MOL DPR DRY VV
DRER1 1776714-0: 000000
DRDA 1776706-0: 000000 SURFACE=0, SECTOR=0
DROF 1776732-0: 000000 OFFSET=0.
DRDC 1776734-0: 000000 DESIRED CYLINDER=0
DRCC 1776736-0: 000000 CURRENT CYLINDER=0
DRER2 1776740-0: 000000
DRER3 1776742-0: 000000
BASIC COMMUNICATION FAULT BETWEEN RH AND DRIVE
WRITE HEADER AND DATA OPERATION DID NOT COMPLETE
M7773 - SN ROW-6
M7788 - MDLI ROW-4 SLOTS A&B
M7789 - MDLI ROW-4 SLOTS E&F
M7776 - EC ROW-5
----------------------------------------
*PGM TRACE* TEST-352 PC-051276
*PGM TRACE* TEST-353 PC-051402
*PGM TRACE* TEST-354 PC-051564
*PGM TRACE* TEST-355 PC-051667
*PGM TRACE* TEST-356 PC-051753
*PGM TRACE* TEST-357 PC-052046
*PGM TRACE* TEST-360 PC-052221
*PGM TRACE* TEST-361 PC-052351
*PGM TRACE* TEST-362 PC-052471
*PGM TRACE* TEST-363 PC-052663 *TEST OMITTED. NO "OPRSEL"*
THE FOLLOWING DEVICES HAVE BEEN TESTED
DRIVE-0 DRIVE TYPE=SINGLE PORTED RP06 DRIVE SER. NO.=0011.
END PASS 1.
SMMON CMD -